Motorola MSC-241 Questions & Answers

Full Version: 108 Q&A


Latest MSC-241 Exam Questions and Practice Tests 2024 - Killexams.com

Latest MSC-241 Practice Tests with Actual Questions


Get Complete pool of questions with Premium PDF and Test Engine


Exam Code : MSC-241
Exam Name : Design and Deploy for MOTOTRBO Solutions EMEA
Vendor Name :
"Motorola"








MSC-241 Dumps MSC-241 Braindumps

MSC-241 Real Questions MSC-241 Practice Test MSC-241 Actual Questions


Motorola


MSC-241


Design and Deploy for MOTOTRBO Solutions EMEA


https://killexams.com/pass4sure/exam-detail/MSC-241



Question: 97

A Dealer installed a Capacity Plus system with 4 voice repeaters. They want to provide GPS service for a local Taxi company, but will install the control stations and Data Revert repeaters after they decide which GPS Location application will best fit their customer’s needs. Initially, 4 radios were programmed as a test to successfully verify Talk group calls, but after 100 radios were added, the radios experienced system busy conditions. Which of the following BEST describes the cause of the Busy condition?


  1. Co-Channel users or RF Interference

  2. Low RF power from the Repeater

  3. Mistuned duplexer or combiner, causing the radios to consume too much battery energy, eventually displaying a busy condition

  4. Automatic Registration Service (ARS) was enabled in the radios, causing them to continuously send registration attempts with no ARS server to acknowledge them




Answer: D



Question: 98

Repeater Diagnostics and Control (RDAC) allows:


  1. A radio user to inquire the status of his portable radio

  2. A radio user to check the telemetry use

  3. A system administrator to monitor and control repeaters within the system

  4. A third party application to diagnose the telemetry statuses




Answer: C



Question: 99

A technician has just installed an additional repeater to a single repeater Capacity Plus system to increase the capacity. The technician programmed the repeater as a peer with the correct frequencies and color code per the customer’s documentation. He then adds a voice channel in the channel pool to the three (3) subscribers with the correct frequencies and color code. He presses PTT and the first two (2)


subscribers each get a voice channel. The third subscriber is showing “Searching.” Which of the following BEST describes the issue?


  1. The technician did not add the newly added voice channel to the Capacity Plus voice member list.

  2. The technician did not add a contact for the newly added voice channel.

  3. The technician did not add the Capacity Plus personality to the zone.

  4. The technician should have programmed the additional repeater as a Master.




Answer: A



Question: 100

A dealer has two repeaters operating in single site mode. He uses RDAC to monitor the radio sites. Yesterday, he was at the site and added a second channel to try out Dynamic Mixed Mode. This morning, he came into the office, changed the repeater to channel 2 and it disappeared off the RDAC screen. Why did this happen?


  1. There is a problem with the IP link.

  2. There is a fault with the repeater.

  3. There is a configuration problem with channel 2.

  4. Dynamic Mixed Mode does not support RDAC.




Answer: D



Question: 101

A mobile radio with three roam lists, two empty RX Group Lists, and ID 71001 is currently working on a customer’s IP Site Connect system but not on their Capacity Plus system. Which of the following BEST describes why this may be happening?


  1. There cannot be more than one roam list.

  2. The RX Group List must have at least one entry in it.

  3. The Radio ID cannot be 71001, it must be equal to or below 65535.

  4. The IP Site Connect radio cannot be used on a Capacity Plus system.




Answer: C



Question: 102

A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and repeaters two (2) and three (3) as peers. The dealer needs to make a simple change in repeater two (2) and utilize IP repeater programming (IRP) to access the repeater remotely. A couple of days later the customer calls and complains about users getting system busy tones (engaged tones). The dealer attempts to connect an RDAC remotely to the system with no success. He has verified he can communicate to the router at the site. Which of the following statements BEST describes the issue?


  1. The master has gone down and taken the rest of the Capacity Plus network with it.

  2. The master has gone down and the system is operating on just two (2) repeaters.

  3. There is RF interference on the channel and the master repeater is unable to communicate to the peers.

  4. The peers are using DHCP and are not able to connect to the master and refresh their peer list. The system is operating on just the master.




Answer: B



Question: 103

Repeater Diagnostics And Control (RDAC) can be used for which of these functions (select TWO)?


  1. Edit Programmed Values

  2. Measure Receive RSSI

  3. MeasureTransmit Power

  4. Read Repeater Log




Answer: B, D



Question: 104

A MOTOTRBO repeater has been programmed for Dynamic Mixed Mode. The repeater supports both analogue users whose radios have been programmed for carrier squelch operation and MOTOTRBO digital users. The analogue users


complain that there is an intermittent buzzing noise on the channel and that a similar buzzing noise can be heard whenever a digital user transmits. What needs to be done to solve this problem?


  1. Tell the MOTOTRBO radio users to only use their analogue channel

  2. Replace the analogue radios with MOTOTRBO radios

  3. Reprogram the radios and repeater with a PL tone

  4. Reprogram the repeater only with a PL tone




Answer: D



Question: 105

A MOTOTRBO repeater is connected to a Zetron Model 35 Telephone Interconnect. If a telephone user dials the Telephone Interconnect number, they get a busy signal (engaged tone). If a radio user dials any telephone number, they don’t hear the ringing tone, only silence. Upon visiting the site, you find that when a radio user dials, the relay click can be heard from the Zetron Model 35. Unplugging the RJ11 and dialing the Telephone Interconnect, still results in a busy signal (engaged tone). With this information, what do you think could be wrong?


  1. The Zetron Model 35 may be faulty.

  2. The Zetron Model 35 has probably not been configured for the phone line Ringer Equivalence

    Number (REN).

  3. The RJ11 cable may have a short circuit or there is a short circuit somewhere between the site and the exchange.

  4. The repeater interface cable to the Zetron Model 35 is faulty.




Answer: C



Question: 106

A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and repeaters two (2) and three (3) as peers. On the 24th of May, there is a lighting strike at the site and the building lost power, causing the three repeaters to revert to DC power. The design of the site called for just the repeaters to be battery backed. However the next morning the customer calls and reports that a number of talkgroups are getting busy tones (engaged), yet other groups are seeing no busy


tones (engaged) on the system. Which of the following statements BEST describe the issue?


  1. The master has gone down and taken the rest of the Capacity Plus network with it.

  2. The peers use DHCP and were not able to connect to the master and refresh their peer list and went off the Capacity Plus network as their leases expired.

  3. The switch was not on battery backup and there are no LAN connections on the Capacity Plus system, each of the repeaters are now operating as three (3) independent Capacity Plus systems.

  4. The peers use DHCP and were not able to connect to the master and refresh their peer list. The dealer should have used static IP addresses throughout.




Answer: C



Question: 107

Customers using a 3 site IP Site Connect system are complaining that around lunchtime on weekdays their audio on wide area calls becomes garbled and is sometimes not heard at all sites. All calls on the local slots seem to be fine. What is the BEST first troubleshooting step?


  1. Have all radio users document where they are at lunch time every day of the week and see if there is a coverage problem in that area.

  2. Change the admit criteria to impolite in the radios so they transmit over co- channel users. C. Check the Quality of Service (QoS) for port 50,000 in the network routers so that the IP Site Connect system has higher priority on the customer IP network over computer users surfing at lunch time.

  1. Check all inbound and outbound frequencies for co-channel users around lunchtime.

  2. Lower the number of radio users on the wide area channel since there are too many, which is causing collisions and blocking.




Answer: C



Question: 108

An amusement park customer has alphanumeric display portables with built-in GPS receivers. They have expanded their Capacity Plus system a couple of times, by purchasing additional radios and repeaters. In the most recent purchase, they


added an AVL server to track their employee locations. The voice side of the system works flawlessly. Most radios register and report their location as expected. There are a few radios that register into the AVL server, but never report their location. The radios show the following icon on the screen. What is the MOST likely cause for this issue (select TWO)?


  1. The GPS receivers are defective from the factory. Collect the radios and send them into repair.

  2. The antenna used is the wrong model. Check the colored rings on the antennas.

  3. The antenna is not properly tightened onto the radio.

  4. The radios need to have the GPS function enabled in the code plug.

  5. Those particular users need Public Safety Microphones to move the antenna above the user’s shoulder.




Answer: B, C


User: Mika*****

I am pleased to say that I passed the msc-241 exam, and I could not have done it without your help. My score was higher than I expected, and I attribute it all to your guidance. Thank you very much!
User: Jenny*****

While other candidates spend months preparing for their msc-241 exams, I was able to complete it in just one day with the help of killexams.com. Their registration process was straightforward, and their material was very effective in helping me achieve my certification.
User: Alonso*****

After failing the exam twice, I turned to killexams.com for help. Their guarantee gave me the confidence to purchase their MSC-241 Questions and Answers, and the VCE exam simulator helped me learn how to solve the questions. I simulated the test repeatedly, which helped me focus on the questions on the exam day, and I finally became MSC-241 certified. Thanks, killexams.com!
User: Lyubov*****

I am delighted because I scored very high in my msc-241 exam thanks to Killexams.com. I could not believe I would be able to do it, but Killexams.com made me believe otherwise. The internet educators are doing an excellent job, and I salute them for their determination and devotion to their work.
User: Constance*****

Killexams.com is a highly recommended study kit for those preparing for the MSC-241 exam. As a user of this kit, I can attest that it covers all the topics listed in the official syllabus. The preparation is solid, and it gave me the confidence to take the exam. What more, I was pleasantly surprised that the questions in the kit were the same as those in the actual exam. This just goes to show how effective Killexams.com is in helping you prepare for the MSC-241 exam. So, if you are looking for the best study kit for this exam, look no further than Killexams.com.

Features of iPass4sure MSC-241 Exam

  • Files: PDF / Test Engine
  • Premium Access
  • Online Test Engine
  • Instant download Access
  • Comprehensive Q&A
  • Success Rate
  • Real Questions
  • Updated Regularly
  • Portable Files
  • Unlimited Download
  • 100% Secured
  • Confidentiality: 100%
  • Success Guarantee: 100%
  • Any Hidden Cost: $0.00
  • Auto Recharge: No
  • Updates Intimation: by Email
  • Technical Support: Free
  • PDF Compatibility: Windows, Android, iOS, Linux
  • Test Engine Compatibility: Mac / Windows / Android / iOS / Linux

Premium PDF with 108 Q&A

Get Full Version

All Motorola Exams

Motorola Exams

Certification and Entry Test Exams

Complete exam list