Question: 103


Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.


Which statement about mixing different FLM modules is true?


  1. Existing 2-port FLM modules must be replaced with 4-port FLM modules

  2. A management ring can contain mixed frame link module configurations

  3. A management ring with mixed FLM modules cannot have more than 12 frames

  4. Mixing different FLM modules is allowed if all of them have the same firmware version




Answer: B
Question: 104

Your customer has the following HPE Synergy setup


  • 3 HPE Synergy 12000 Frames


  • 4 HPE Virtual Connect SE 100 Gb F32 Modules


  • 2 HPE Synergy 50 GO Interconnect Link Modules


  • 36 HPE Synergy 480 Gen10 Plus compute modules


  • 2 HPE Composer 2 modules


Which statement about this setup is true?


  1. To use all compute nodes, the customer must create at least two logical enclosures

  2. To manage all frames, the customer must buy two additional HPE Composer 2 modules

  3. The customer must buy 36 HPE OneView Advanced licenses to manage compute modules

  4. The customer can add one D3940 storage Module to each of the frames




Answer: C
Question: 105

Which statement about manual orchestration during the firmware update is true?


  1. It is supported only for logical enclosures with at least three frames

  2. It provides an ability to select and update one side of the Interconnect topology at a time

  3. It provides the ability to install an older firmware version than currently Installed In the interconnect

  4. It allows all the interconnect modules to be activated manually at the same time.




Answer: B
Question: 106

Your customer added a new Ethernet network in HPE Oneview mat is used to manage their HPE Synergy platform.

When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.


What must be done to fix this issue?


  1. Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.

  2. To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.

  3. The newly created network must be added to the uplink set within the LIG, and Logical interconnect configuration must be updated from the LI

  4. Check within the server profile which server hardware is used and perform the Refresh operation on this compute node to get the latest adapter information.




Answer: C
Question: 107 Refer to the exhibit.


Which statement about this logical interconnect group is true?


  1. The master modules are located in the interconnect bays 2 and 5

  2. For the given downlink speed, the maximum number of frames is reached

  3. Both master modules are located in the same HPE S ynergy frame

  4. To use interconnect bay set 3, all compute nodes must be half-height




Answer: C
Question: 108

Which compute node parameters are captured within server hardware type?


  1. Number of the CPUs

  2. installed operating system

  3. Mezzanine card configuration

  4. Size of the memory Installed




Answer: C
Question: 109

Which statement about login redistribution is true?


  1. Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame

  2. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports

  3. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules

  4. Login redistribution is used for login balancing when they are not distributed evenly over the FC links




Answer: C
Question: 110

An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged in a login prompt displays


Where should you start the troubleshooting process?


  1. At the iLO interface to verify whether the ILO Advanced license is properly applied

  2. At HPE OneView Interface to verify whether the server is In the maintenance mode

  3. At the iLO interface to verify whether the SSO certificate is removed from an iL

  4. At HPE OneView Interface to verify whether the iLO processor is disabled




Answer: A
Question: 111

Which statement about HPE Apollo 2000 Gen10 Plus platform is true?


  1. It is equipped with HPE Persistent memory by default

  2. It can support a single processor only and up to 4 per chassis

  3. It is fully managed using HPE OneView including all connections

  4. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs




Answer: D
Question: 112

You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)


  1. HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy

  2. HPE Virtual Connect SE 16Gb FC Module for HPE Synergy

  3. HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy

  4. HPE Virtual Connect SE 32Gb FC Module for HPE Synergy

  5. Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy

  6. Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy



Answer: A,B,D
Question: 113 DRAG DROP

You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView. Put the steps to achieve this goal into the coned order in the answer area on the right.




Answer: A,B,D
Question: 114

A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?


  1. Brocade 32GB Fibre Channel Switch Module for HPE Synergy

  2. HPE virtual Connect SE 32 Gb FC Module for Synergy

  3. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy

  4. HPE Synergy 12 Gb SAS Connection Module




Answer: C
Question: 115

Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.


What must be done to enable dedicated FC connectivity for this HPE Synergy frame?


  1. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.

  2. For Brocade switches, a logical interconnect group must be created in HPE OneView.

  3. For VC-FC modules, all of server facing ports must be property licensed.

  4. SAS switches must be moved to second fabric and FC modules Installed in the first one.




Answer: D
Question: 116

Which statement about the HPE D3940 storage module is true?


  1. SATA drives requires redundant 10 adapters to be installed in this module

  2. Up to five modules can be installed in a single frame with Gen10 servers

  3. it is configured through CLl available from HPE Synergy console

  4. Only one type of drives (SATA, SAS, SSD) can be installed in each module




Answer: C
Question: 117

Which statement about HPE Superdome Flex 280 is true?


  1. It supports 2 to 8 sockets in 2-socket increments.

  2. it cannot be managed using HPE OneView.

  3. It must be equipped with at least 768 GB of memory.

  4. It can support up to two nPars with an external RM




Answer: A
Question: 118

Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.


  1. HPE Composer Maintenance Console

  2. HPE OneView Update Readiness Checker

  3. HPE OneView Global Dashboard

  4. HPE OneView Firmware Compliance Report




Answer: B
Question: 119

Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customerĂ¢s needs?


  1. Rack Management Controller for nPar management

  2. HPE Superdome Flex Grid licenses enabling connectivity between chassis

  3. At least Tour HPE Persistent Memory DIMMs per nPar

  4. One base chassis and three expansion chassis with licenses




Answer: D


User: Arthur*****

Due to my demanding daily routine and long commutes, I did not have time to prepare for my HPE0-S59 exam. That is, until a friend told me about killexams.com, which proved to be a game-changer. I was able to easily prepare for the exam on the go using my laptop, and killexams.com resources were reliable and outstanding.
User: James*****

I have been using killexams.com for all my tests, and last week, I passed the hpe0-s59 exam with an excellent mark using their Questions and Answers test resources. I had some doubts about some subjects, but the material cleared all my doubts. Thanks for providing me with the robust and reliable practice test. It is a great product.
User: Slavka*****

I had trouble preparing for the hpe0-s59 exam, so I turned to Killexams.com for help. Their dedication to providing useful and accurate material made all the difference. The hpe0-s59 exam is not easy, but their questions and answers were relevant and up-to-date, which helped me score remarkably well on the exam.
User: Olenka*****

I had delayed taking the hpe0-s59 exam due to my busy schedule at work. But after discovering the questions and answers provided by killexams.com, I felt motivated to take on the test. The material was supportive and helped me resolve my doubts about the hpe0-s59 topic. I was extremely happy to pass the exam with an excellent score of 97%. Thank you, Killexams, for your incredible support.
User: Elena*****

I needed an exam simulator for my HPE0-S59 exam, and killexams.com came to my rescue. The material they provided was so comprehensive that I was able to answer all questions within just ninety minutes. The practice tests had all the crucial information I needed, and I was able to pass the exam with ease. Initially, I was hesitant to use killexams.com, but after downloading their demos, I realized how helpful their material was.

Features of iPass4sure HPE0-S59 Exam

  • Files: PDF / Test Engine
  • Premium Access
  • Online Test Engine
  • Instant download Access
  • Comprehensive Q&A
  • Success Rate
  • Real Questions
  • Updated Regularly
  • Portable Files
  • Unlimited Download
  • 100% Secured
  • Confidentiality: 100%
  • Success Guarantee: 100%
  • Any Hidden Cost: $0.00
  • Auto Recharge: No
  • Updates Intimation: by Email
  • Technical Support: Free
  • PDF Compatibility: Windows, Android, iOS, Linux
  • Test Engine Compatibility: Mac / Windows / Android / iOS / Linux

Premium PDF with 122 Q&A

Get Full Version

All HP Exams

HP Exams

Certification and Entry Test Exams

Complete exam list