HP HPE6-A66 Questions & Answers

Full Version: 159 Q&A


Latest HPE6-A66 Exam Questions and Practice Tests 2024 - Killexams.com

Latest HPE6-A66 Practice Tests with Actual Questions


Get Complete pool of questions with Premium PDF and Test Engine


Exam Code : HPE6-A66
Exam Name : Aruba Certified Design Associate (ACDA)
Vendor Name :
"HP"








HPE6-A66 Dumps HPE6-A66 Braindumps

HPE6-A66 Real Questions HPE6-A66 Practice Test HPE6-A66 Actual Questions


killexams.com


HP


HPE6-A66


Aruba Certified Design Associate (ACDA)


https://killexams.com/pass4sure/exam-detail/HPE6-A66


Question: 145


When a WLAN has to support nomadic devices, a network architect must primarily plan for which component in their design?


  1. type of users

  2. number of users per location

  3. mobility requirements and usage

  4. density of users




Answer: C
Question: 146

Which two challenges do802.1ig barcode scanners present to a WLAN design? (Select two.)


  1. roaming between APs

  2. encountering RF interference by devices

  3. determining the RF channel bandwidth consumed per Barcode scanner

  4. implementing adequate security measures to ensure PCI compliance

  5. providing consistent performance on all available channels




Answer: A,D,E
Question: 147

A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.


  1. Given this information, which Aruba solution would be the most cost-effective while still meeting the customer's requirements? O An IAP cluster per floor

  2. A standalone 7008 controller per floor

  3. Two 7205 mobility controllers in a cluster

  4. Two 7030 mobility controllers in a cluster




Answer: A
Question: 148

Which must you perform in IRIS to assign a device to a Design Group?


  1. Right-click the device and select Set Layer Membership

  2. Right-click the device and select Set Design Group

  3. Drag and drop the device into the Site

  4. Drag and drop the device into the Design Group




Answer: D
Question: 149

A network architect is designing a wireless solution for a company that is leasing one floor in a multi-floor building in a downtown area. The customer is concerned about ensuring complete Wi-Fi coverage and pin-pointing RF hazards.


What type of survey should the network architect perform?


  1. Active

  2. Virtual

  3. Passive

  4. Spectrum clearing




Answer: A
Question: 150

A customer placed an order for an ArubaOS 5406R switch and plans to rack mount it in a wiring closet. The dimensions of the switch are 17.5 inches wide (44.45 cm), 6.9 inches high (17.5 cm), and 17.75 inches deep (45.1 cm).


How many rack units should a customer plan for this switch?


  1. 5

  2. 4

  3. 6

  4. 3




Answer: C
Question: 151

A wiring closet with a POE+ switch is 250 feet (76 meters) away from an AP on a building floor. The AP's smart-rate port is connected to a smart-rate port on the switch, which is capable of 10 Gbps. The cable type is Cat5e STP.


What is the maximum speed that the customer can expect from the connected AP?


  1. 2.5 Gbps

  2. 1 Gbps

  3. 5 Gbps

  4. 10 Gbps




Answer: A
Question: 152

A customer has some employees that travel to various locations, where these employees will need Wi-Fi access at these locations. Because many of these locations do not have wireless support, the employees will need to carry an AP solution with them. Internet connectivity, if it doesn't exist at these locations, will be provided by a national phone company USB wireless card which will be connected to AP. The wireless solution needs minimal bandwidth, but needs to minimally support 802.1 lac wave 1 devices.

Which Aruba AP wireless solution would meet the needs of these employees most effectively and cost efficiently? A. 318

  1. 303H

  2. 365

  3. 203R




Answer: D
Question: 153

NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a drop-down ceiling at 10 feet (3 meters).


The network architect has given you one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.



This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters).


Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor?


  1. 55.750 square feet {5,175 square meters)

  2. 56.350 square feet {5,235 square meters)

  3. 47.000 square feet {4,365 square meters)

  4. 338,100 feet {31,410 square meters)




Answer: B
Question: 154

A network architect is redesigning a wireless network. The architect begins by analyzing the number of spatial streams supported by APs of various vendors as well as the wireless devices currently in the network, if the company wants to ensure that new wireless design, including user wireless devices, support Multi-User MIMO (MU-MIMO).

Which standard or standards must the wireless products support?


  1. Only 802.11ax and 8011.ac

  2. Only 802.11ax

  3. Only 802.11ax,802.1lac, and 802.l1n

D. Only 802.11ax,802.11ac, 802.11n, and 802.11a




Answer: C
Question: 155

A network architect is given the task to design a new network solution for NewStellar Company, Inc. NewSteiiar has a main corporate campus in a business park with two adjacent buildings.


The network architect has given one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.



Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. Each floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet {870 square meters).


Because of security concerns, video cameras will be installed throughout the facility. There are 16 of these per floor, 8 per wiring closet. The cameras are non-WiFi capable and require POE 802.3af-capable switch ports from which to draw power.


A wireless capacity design is required. Assuming that wireless coverage is required across the Building 1, Floor 2, including the central area, and that half the required APs will connect to each wiring closet, approximately how many POE+ ports will be required per wiring closet for all devices that have POE or POE+ needs?


  1. 30

  2. 22

  3. 42

  4. 8




Answer: A
Question: 156 Refer to the exhibit.


When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance?


  1. A + C

  2. A + B

  3. A + B + C + D

  4. A + B + C




Answer: C
Question: 157

A company is redesigning their wireless network and will be upgrading all devices to support the latest wireless standards. The company is not near any radar installations.


In order to keep wireless NIC power levels as low as possible to reduce interference issues and to take advantage of radar frequency ranges, what IEEE standard should APs support?


A. 802.11r B. 802.11 ax C. S02.11V D. S02.11h




Answer: B
Question: 158

A network architect has created two sites in IRIS and defined network devices for each site. From which window would a network architect connect the two sites together?

  1. Topology

  2. Site-1

  3. Catalog

  4. Start Page




Answer: B
Question: 159

A network architect is creating a new wired design for a warehouse building.

As a best practice, what length should the architect allow for the service loop in the wiring closets in this environment? A. 3-10 feet (1-3 m)

B. 3 feet (1 m)

C. 15-30 feet (5-10 m)

D. 30-60 feet (10-20 m)




Answer: B


User: Iman*****

Thank you, killexams.com, for offering this question bank and providing me with the necessary help to score 78% in the HPE6-A66 exam.
User: Natan*****

Preparing for the HPE6-A66 exam can be a challenging process, and the odds of failing are high without proper guidance. Thats where high-quality exam preparation material like Killexams.com comes in. It provides valuable information that not only complements your preparation but also increases your chances of passing the exam with flying colors. I organized my preparation with their material and scored an impressive 42 out of 50. Trust me, this material will not disappoint you.
User: Tatiana*****

I have been using killexams.com for all my tests, and last week, I passed the HPE6-A66 exam with an excellent mark using their Questions and Answers test resources. I had some doubts about some subjects, but the material cleared all my doubts. Thanks for providing me with the robust and reliable practice test. It is a great product.
User: Oliver*****

Killexams.com practice tests website helped me access several exam preparation materials for my hpe6-a66 exam. I was unsure which one to choose, but their sample questions helped me pick the right one. I purchased their practice tests package, which helped me understand the critical concepts required for the exam. I was able to answer all the questions on time. I am delighted to have Killexams.com as my education provider. Thank you so much.
User: Fatema*****

The Killexams.com website provided me access to several exam training materials for the HPE6-A66 exam. I was initially unsure which one to choose, but the samples on the website helped me select the quality one. I purchased the Killexams.com practice tests, which helped me understand the essential concepts and answer all questions in a timely manner. I am happy to have Killexams.com as my coach.

Features of iPass4sure HPE6-A66 Exam

  • Files: PDF / Test Engine
  • Premium Access
  • Online Test Engine
  • Instant download Access
  • Comprehensive Q&A
  • Success Rate
  • Real Questions
  • Updated Regularly
  • Portable Files
  • Unlimited Download
  • 100% Secured
  • Confidentiality: 100%
  • Success Guarantee: 100%
  • Any Hidden Cost: $0.00
  • Auto Recharge: No
  • Updates Intimation: by Email
  • Technical Support: Free
  • PDF Compatibility: Windows, Android, iOS, Linux
  • Test Engine Compatibility: Mac / Windows / Android / iOS / Linux

Premium PDF with 159 Q&A

Get Full Version

All HP Exams

HP Exams

Certification and Entry Test Exams

Complete exam list